Flange Fixed or Welded Ese Lightning Rod for Airport and Aerodrome

Product Details
Customization: Available
Type: Signal Type Arrester
Structure: Steel

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
60
Year of Establishment
2006-07-30
  • Flange Fixed or Welded Ese Lightning Rod for Airport and Aerodrome
  • Flange Fixed or Welded Ese Lightning Rod for Airport and Aerodrome
  • Flange Fixed or Welded Ese Lightning Rod for Airport and Aerodrome
  • Flange Fixed or Welded Ese Lightning Rod for Airport and Aerodrome
  • Flange Fixed or Welded Ese Lightning Rod for Airport and Aerodrome
  • Flange Fixed or Welded Ese Lightning Rod for Airport and Aerodrome
Find Similar Products

Basic Info.

Model NO.
YBT-YFD60
Installation
Parallel Arrester
Application
Substation
Size
Small
Operation Voltage
High Voltage
Shape
Round
Material
Q304 Steel
Certification
ROHS, ISO9001, CCC
Early Discharge Time
60 μs
Installation Method
Flange Fixed or Welded
Operating Hours
All Day
Outward Appearance
Beautiful and Easy Install
Features
No Need Power
Transport Package
Non Fumigation Wooden Box
Specification
304 stainless steel
Trademark
YANGBO
Origin
China
Production Capacity
100000

Product Description

Small and medium-sized radar vehicles or special vehicles have higher requirements for lightning protection equipment to prevent lightning strikes from causing damage to precision equipment. The ESE air-termination device has passed the lightning test of the WHVRI High Voltage Research Institute. The maximum peak current test is N/100KA, and it can generate electricity 60microsecond in advance. Due to its light weight and good high pressure resistance, it is recommended to be used in places with high requirements.Flange Fixed or Welded Ese Lightning Rod for Airport and Aerodrome

 

Flange Fixed or Welded Ese Lightning Rod for Airport and Aerodrome

 

Flange Fixed or Welded Ese Lightning Rod for Airport and Aerodrome
YBT-YFD60 Lightning Rod Protection Radius(NFC 17-102)
category Class 1 protection Class 2 protection Class 3 protection
model 18 31 45 60 18 30 45 60 18 30 45 60
Height(m) Protection radius(m)
2 14 19 25 32 19 25 32 40 22 28 36 44
2 21 28 38 48 29 38 48 59 33 42 57 65
4 28 38 51 64 38 50 65 78 44 57 72 87
5 35 48 63 79 49 63 81 97 55 71 89 107
6 35 48 63 79 49 64 81 97 56 72 90 107
8 36 49 64 79 51 65 82 98 58 73 91 108
10 37 49 64 79 52 66 83 99 60 75 92 109
15 38 50 65 80 55 69 85 101 64 78 95 111
20 38 50 65 80 58 71 86 102 67 81 97 113
45 38 50 65 80 63 75 90 105 77 89 104 119
60 38 50 65 80 63 75 90 105 78 90 105 120

 

Flange Fixed or Welded Ese Lightning Rod for Airport and Aerodrome

 

Flange Fixed or Welded Ese Lightning Rod for Airport and AerodromeEquipped with energy storage components, it has the ability to trigger the upward leader.
Optimize the head radius to reduce the corona effect and ensure the normal operation of the pulse device.

LIGHTNING ROD CHARACTERISTICS

1.The electronic components are completely wrapped in epoxy resin to prevent internal electronic components from being damaged by lightning strikes.
2.No radioactive elements, safe and reliable; stainless steel material,corrosion-resistant,beautifulappearance.
3.Accurately judge the timing of discharge,make lightning strikes more accurate, and reduce the probability that the lightning strike point falls on a non-lightning rod body.
4.Fully active system, self-activating.

LIGHTNING ROD INSTALLATION
1.Determine building lightning protection based on the area and height of the protected building,the number oflightning days in the location, the geographical environment correction coefficient, the nature ofthe building's use,etc.
2.The down conductors (down conductors) should be electrically connected to the main steel bars of the building,or two or more down conductors (down conductors) should be made as required.
3.The down conductor (down conductor) should be disconnected and insulated on the ground nearby.
4.The grounding body, grounding resistance, and lightning protection ground network should be implemented in accordance with the lightning protection standard GB50057-2010.

Flange Fixed or Welded Ese Lightning Rod for Airport and Aerodrome

 

Flange Fixed or Welded Ese Lightning Rod for Airport and Aerodrome

 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier